EI70 Dual-Loop Grounding Monitor
EI70 dual-loop grounding monitor is mainly used to monitor the grounding of wrist straps, bench hooks and equipment on the anti-static workbench in EPA area, and is able to transfer the data regarding the grounding of such wrist straps, bench hooks and equipment to a PC via a converter for data collection. Generally, the monitor is installed on the upper right or left corner or the bottom of the anti-static workbench.
Product Features:
Apply resistive dual-loop monitoring to ensure reliable grounding of monitoring articles
Can simultaneously monitor the grounding of operator, workbench and all equipment. The bench hook monitor can be configured to monitor the equipment (the client needs to propose such request before delivery)
The data regarding the grounding of wrist straps, bench hooks and equipment monitored can be transferred to a PC via a converter to acquire monitoring data.
Sound and visual alarms
Function Description:
EI701 can monitor the grounding of 2 wrist straps, 1 bench hook and 1 set of equipment at the same time;
EI702 (EI702A) can monitor the grounding of 4 wrist straps and 1 bench hook at the same time;
EI703 can monitor the grounding of 6 wrist straps, 1 bench hook and 1 set of equipment at the same time;
EI705 can monitor the grounding of 4 sets of equipment at the same time;
EI706 can monitor the grounding of 4 bench hooks at the same time;
Technical Parameters:
Functions |
Technical Parameters |
|
Monitoring resistance(Ohms) |
1. The range of the resistance value on the monitoring of the grounding of anti-static bench hook is 0-3.5MΩ, the ex-factory upper limit is 3.5MΩ
2. The range of the resistance value on the monitoring of the grounding of equipment and facilities is 0-100Ω, the ex-factory upper limit is 4Ω
|
|
Monitoring voltage value(V) |
1.The voltage value on the monitoring of bench hook is 3.2V (3.5MΩ) (can be configured according to requirements)
2.The voltage value on the monitoring of equipment and facilities is less than 0.4V (can be configured according to requirements)
3.The monitoring voltage of wrist strap operation (35MΩ) is 3.5V
|
|
Monitoring accuracy (%) |
The monitoring accuracy of resistance value is 15% | |
Operating temperature |
-10~50℃ |
|
Shell |
Aluminum alloy | |
Power supply |
Input: 110~220VAC/50~60HZ, output: 9VDC/1A |
|
Maximum power |
9W |
|
Model |
EI701/702/705/706 |
EI703 |
Volume (mm) |
140*112*36 |
180*130*34 |
Weight (Kg) |
0.35 |
0.54 |
Network diagram: